方案介紹 / plan description

UPS(UninterruptiblePowerSystem/UninterruptiblePowerSupply),即不間斷電(dian)(dian)(dian)(dian)(dian)(dian)(dian)源,是將(jiang)(jiang)(jiang)蓄(xu)(xu)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(多(duo)為鉛酸免維護(hu)蓄(xu)(xu)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)池(chi))與主機(ji)(ji)(ji)相連接,通(tong)過(guo)(guo)主機(ji)(ji)(ji)逆變器等(deng)模塊電(dian)(dian)(dian)(dian)(dian)(dian)(dian)路將(jiang)(jiang)(jiang)直(zhi)流電(dian)(dian)(dian)(dian)(dian)(dian)(dian)轉換(huan)成市(shi)(shi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)的(de)系統設備(bei)(bei)。主要用于給單臺計算機(ji)(ji)(ji)、計算機(ji)(ji)(ji)網絡系統或其(qi)它電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)子設備(bei)(bei)如(ru)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)磁閥、壓(ya)力(li)變送器等(deng)提供穩定、不間斷的(de)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)供應(ying)。當市(shi)(shi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)輸入(ru)正(zheng)常時(shi),UPS將(jiang)(jiang)(jiang)市(shi)(shi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)穩壓(ya)后(hou)供應(ying)給負載使(shi)用,此時(shi)的(de)UPS就(jiu)是一臺交流市(shi)(shi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)穩壓(ya)器,同(tong)時(shi)它還向(xiang)機(ji)(ji)(ji)內電(dian)(dian)(dian)(dian)(dian)(dian)(dian)池(chi)充電(dian)(dian)(dian)(dian)(dian)(dian)(dian);當市(shi)(shi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)中斷(事故停電(dian)(dian)(dian)(dian)(dian)(dian)(dian))時(shi),UPS立(li)即將(jiang)(jiang)(jiang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)池(chi)的(de)直(zhi)流電(dian)(dian)(dian)(dian)(dian)(dian)(dian)能(neng),通(tong)過(guo)(guo)逆變零切換(huan)轉換(huan)的(de)方法向(xiang)負載繼續(xu)供應(ying)220V交流電(dian)(dian)(dian)(dian)(dian)(dian)(dian),使(shi)負載維持正(zheng)常工作并保(bao)護(hu)負載軟、硬件不受損(sun)壞(huai)。UPS設備(bei)(bei)通(tong)常對電(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)過(guo)(guo)高或電(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)過(guo)(guo)低(di)都能(neng)提供保(bao)護(hu)。

UPS電源系統
電氣示意圖 & 配電架構圖 / Schematic diagram
  • 示意圖
  • 構架圖
UPS推薦 / Products Recommended
UPS2000-G

FusionModule800采用(yong)的(de)UPS為UPS2000-G。根據用(yong)戶的(de)實際需求,為其提供合適(shi)的(de)UPS系統。UPS2000-G工(gong)作在380V/400V/415V電(dian)源制式下(xia),具有(you)多(duo)重保(bao)護、高可(ke)靠(kao)性、智(zhi)能簡(jian)單,柔性擴容、高效節能、綠色環(huan)保(bao)等(deng)特點(dian)。 UPS2000-G外觀圖如左圖所示。

參數類型 參數名稱 20kVA
輸入參數 輸入電壓范圍 80V AC~280V
AC(80V AC~176V AC間,負載在
40%~100%間線
性降額。)
輸入功率因數
(100%負載下)
> 0.99,單相輸入
> 0.95,三相輸入
額定輸入電壓 380V AC/ 400V
AC /415V AC(三相)
輸入頻率范圍 40Hz~70Hz
輸出參數 額定容量 20kVA
額定電壓 220V AC/ 230V AC/ 240V AC(單相輸出,通過LCD 設置電壓等級來選擇不同的電壓
制式。)
功率因數 0.9
最大效率 94.5%
輸出電壓精度 ±1%
動態電壓瞬變 ±5%
波峰因數 最高可達3:1
過載能力
  • 市電模式,105%~125%負載下:5Min,旁路正常轉旁路,旁路異常直接切斷輸出。
  • 市電模式,125%~150%負載下:1Min,旁路正常轉旁路,旁路異常直接切斷輸出。
  • 市電模式 ≥ 150%負載下:0.1s,旁路正常轉旁路,旁路異常直接切斷輸出。
外形尺寸 高×寬×深 86mm×430mm×585mm
  安裝方式 機架式
防雷 符合IEC/EN60240-2
IEC/EN61000-4-5
YD/T1095-2000 YD/T944-2007
交流輸入端滿足D 級防雷的要求(差、共模5kA,8/20μs)
環境參數 接口類型 電總/干接點/WEB/Modbus/SNMP(Simple Network Management Protocol)
運行溫度 0℃~40℃
相對濕度 0% RH~95% RH,無凝露
最大海拔高度 < 1000m(1000m~4000m參考IEC62040-3降額)
儲存和運輸溫度 -40℃~+70℃(電池包:-20℃~+40℃)
案(an)例展(zhan)示Case Show
震雄集團-4F機房改造項目

震雄集團-4F機房改造項目

震雄集團-4F機房改造項目方案:主要包含天地墻裝修、防雷接地、機房強弱電橋架、機房照明、機房動力環境監控、氣體滅火系統、......
勤誠達總部-機房建設工程

勤誠達總部-機房建設工程

勤誠達總部-機房建設工程項目主要包含:微模塊機柜、機房專用消防系統、機房動環管理系統、機房門禁、監控系統、接地工程及防雷......
珠海綜合布線施工

巨濤-珠海綜合布線施工

工程概況:該項目主要涉及了一樓副樓綜合布線及會議室地面與墻面線槽預留等;其中涉及的設備大致包含有:無線接入控制器、無線a......